This MV single‑core copper XLPE PVC power cable (IEC 60502‑2) with CTS or CWS metallic screen is our best‑seller for fixed indoor, outdoor and underground laying. Complying with IEC 60228, IEC 60332‑3‑24 and relevant LSZH standards, this unarmoured medium-voltage electric cable passes full routine and type tests such as power frequency withstand voltage and partial discharge tests. Supplied by Taitong Cable, a reliable Chinese manufacturer, these Cu/XLPE/PVC cables up to 35kV allow custom sheath colours and various variants. Supported by our in‑house R&D team for steady quality, we serve grid, industrial and renewable projects in Asia, Africa and Southeast Asia; equivalents conforming to local regional standards are offered for other markets, with prompt after‑sales service.
Taitong Cable supplies MV single‑core power cables, Cu XLPE insulated, CTS or CWS copper screen, PVC sheath to IEC 60502‑2, equivalent to European type N2XSY. Certified with ISO9001, CE and full IEC type test reports. Built with high‑purity copper conductor and XLPE insulation, this medium voltage single core electric cable features copper tape screen (CTS) or copper wire screen (CWS) for stable electric‑field control. The durable PVC outer sheath offers solid mechanical and moisture protection with competitive cost.
As a professional cable manufacturer in China, our medium voltage XLPE single core power cable is widely specified for fixed medium‑voltage installation in substations, underground ducts, cable trenches, industrial facilities and renewable energy distribution. this MV power cable is frequently searched as IEC 60502-2 cable, CTS screened MV cable, CWS screen cable and PVC sheathed MV cable by global buyers. Ideal for EPC contractors, power utilities and electrical project buyers. Taitong Cable support custom conductor cross-sections and can provide complete technical documentation upon clients' request.
Construction of Medium Voltage Copper XLPE PVC Power Cables
Copper Conductor: Plain annealed copper, Class 2 stranded (IEC 60228) to reduce overall diameter and maximize current-carrying capacity and withstands short-circuit currents.
XLPE Insulation: Extruded cross-linked polyethylene (XLPE). Serves as the primary dielectric barrier with high insulation resistance, low dielectric loss, and a continuous operating temperature rating of +90°C.
Insulation Screen (Outer Semiconductive Layer): Extruded bonded or strippable semiconductive compound applied over the XLPE core maintains a uniform electric field and controls electrical stress concentration.
Metallic Screen: Copper tape or copper wire screen provides an earth-fault current path, maintains earth potential, and reduces electromagnetic interference (EMI).
(Note: Magnetic metallic armour is generally omitted on single-core AC medium-voltage cables to prevent excessive inductive heating).
Outer PVC Sheath: Polyvinyl chloride (PVC) compound Type ST2 forms a robust outer sheath to protect internal components from moisture, chemical corrosion, weathering and mechanical abrasion.
Applications of Single‑Core MV Cu XLPE PVC Power Cables
These single‑core medium‑voltage copper XLPE PVC power cables are designed for fixed indoor, outdoor and underground laying within medium‑voltage distribution networks.
1, Urban and municipal power grid: Connection between distribution substations, ring main units and transformer stations for urban power supply.
2, Industrial power systems: Power feed for heavy‑duty workshops, production lines, pumping stations and industrial auxiliary facilities.
3, Commercial complex supply: Medium‑voltage incoming and outgoing lines for shopping malls, office buildings, hospitals and data centres.
5, Underground trench or direct burial installation: Laying in cable trenches, cable tunnels or direct burial under normal soil conditions without explosive gas.
6, Outdoor overhead‑to‑underground transition: Transition segments between overhead MV lines and underground cable networks.
Standards
IEC 60228 (Conductors of insulated cables, Class 2 compact stranded copper)
IEC 60502‑2 (Medium voltage extruded XLPE power cables, base type test standard)
IEC 60332‑3‑24 (Flame propagation test for bunched cables, Category C flame retardancy)
IEC 60754‑1 / IEC 60754‑2 (Halogen content and corrosive acid gas emission test for LSZH version)
IEC 61034‑2 (Smoke density measurement under fire condition for low‑smoke cables)
MV single‑core Cu/XLPE/CTS or CWS Screen/AMA Armour/PVC
The cable adopts aluminium wire armour (AMA) over the metallic screen, delivering robust mechanical protection against heavy mechanical load, rock impact and abrasion for direct burial and tunnel laying.
MV single‑core Cu/XLPE/CTS or CWS Screen/ATA Armour/PVC
The cable is fitted with aluminium tape armour (ATA) above the metallic screen, offering reliable mechanical shielding against mechanical damage, moisture and stone impact for underground and duct installation.
Magnetic steel tape armour is generally omitted on single‑core AC medium‑voltage cables, and non‑magnetic aluminium armour is used where mechanical protection is required to prevent excessive inductive heating.
(These standards cover conductor resistance, power frequency withstand voltage, partial discharge, insulation resistance, thermal ageing, flame spread, halogen content, acid gas and smoke density tests.)
Electric Parameters of Unarmoured MV CU/XLPE/PVC Electric Cable
(NOTE The voltages given above are the correct designations although in some countries other designations are used, e.g. 3,5/6 – 5,8/1 0 – 1 1 ,5/20 – 1 7,3/30 kV.)
Maximum Conductor Operating Temperature: 90°C (continuous).
Short-Circuit Temperature: 250°C (for up to 5 seconds).
Conductor cross‑section: Typically 10 to 400 mm²; larger sizes available upon enquiry.
The oversheath is normally black, but a colour other than black may be provided by agreement between the manufacturer and customer, subject to its suitability for the particular conditions under which the cable is to be used.
Routine test: 3.5 U₀, 5 min power frequency withstand; partial discharge ≤10 pC @ 1.73 U₀
Type test: thermal ageing, hot set, sheath test; flame & smoke tests per IEC 60332‑3‑24, IEC 60754‑1/2, IEC 61034‑2
(Static vs. Dynamic: The tighter limit applies only to a fixed, finished bend after installation. While being pulled through ducts or around corners (dynamic pulling), a wider radius and cable rollers/shoes should be used.)
Download the PDF for the relevant cable model to view full technical parameters.
Why choose Taitong Cable as your reliable supplier of MV power cables?
As a trusted Chinese manufacturer and supplier of medium‑voltage power cables, Taitong Cable was established in 2002. Boasting more than two decades of industry experience, we operate 5 large production bases separately for power cables and rubber cables, backed by more than 30 local customer service offices nationwide. Our best‑seller, unarmoured MV single‑core power cables (Cu, XLPE, CTS or CWS Screen, PVC sheath), and its extended variants are widely applied in national grid networks, urban distribution systems, heavy industrial workshops, solar and wind power stations, pumping stations and tunnel power supply projects throughout Asia, Africa and Southeast Asia.
All our cables are manufactured in compliance with IEC international standards, and we are capable of producing products that meet BS, EN, DIN VDE and HD specifications upon customer demand. Every cable supplied by Taitong Cable undergoes strict routine and type tests covering conductor resistance, power frequency withstand voltage, partial discharge, insulation resistance and thermal ageing; flame‑retardant and LSZH versions additionally complete flame propagation, halogen emission and smoke density tests in line with IEC 60332‑3‑24, IEC 60754‑1/2 and IEC 61034‑2. Customisation of insulation and outer sheath colours is available to satisfy unique project requirements.
Equipped with an in‑house R&D team and professional technical engineers, Taitong Group achieves smooth coordination among research, engineering, sales and production teams to expand our global market share. The cable factories continuously introduce advanced production and testing equipment to maintain reliable, good quality. Our technical staff can provide feasible alternative cable solutions when needed, assist customers in solving on‑site technical difficulties, and deliver responsive after‑sales service for all medium‑voltage cable orders around the world.
As a leading China cable manufacturer, Taitong Cable provides agents with high-quality products, competitive factory-direct prices, professional technical support, perfect after-sales service and favorable cooperation policies.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy